HT Italia HT96U 1-100-1000A/1V AC Current Transducer ClampHT Italia HT96U 1 100 1000A 1V AC Current Transducer Clamp Key Features At A Glance Three selectable AC current ranges 1 A, 100 A, and 1000 A full scale with a 1 V AC output signal Measuring range spans 1 mA up to 1200 A AC across the three selectable ranges Maximum error of 2% of reading over a 40 Hz to 10 kHz frequency range Overvoltage category CAT III 600 V, pollution degree 2 according to IEC 1010 1 Diode protection with dielectric strength of 5.
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

HT Italia HT96U 1-100-1000A/1V AC Current Transducer Clamp

Key Features At A Glance

  • Three selectable AC current ranges — 1 A, 100 A, and 1000 A full scale — with a 1 V AC output signal
  • Measuring range spans 1 mA up to 1200 A AC across the three selectable ranges
  • Maximum error of 2% of reading over a 40 Hz to 10 kHz frequency range
  • Overvoltage category CAT III 600 V, pollution degree 2 according to IEC 1010-1
  • Diode protection with dielectric strength of 5.5 kV at 50 Hz for 1 minute
  • Accepts conductors up to 54 mm diameter or bus bars of 35x35 mm or 50x12 mm
  • 2 m output cable with Hypertac connector; operating temperature -10 to +50 °C

The HT Italia HT96U is a clamp-type AC current transducer that converts a measured alternating current into a proportional 1 V AC output signal. It provides three selectable full-scale ranges — 1 A, 100 A, and 1000 A — with corresponding measuring ranges of 0.001 to 1.2 A, 0.1 to 120 A, and 1 A to 1200 A AC, and applies output ratios of 1 mV/mA, 10 mV/A, and 1 mV/A respectively across those ranges.

A current transducer clamp couples around a conductor to sense the AC current flowing through it without breaking the circuit, presenting a scaled low-level output that a host instrument can read. The HT96U is also configured for power measurement: the conventional current direction P1 ⇒ P2 indicated by the arrow must be observed so that the sensed quantity carries the correct sign.

ValueTronics stocks and holds its own inventory in a 20,000 square foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois.

Product Core & Specifications

Specification Value
General Specifications
Selectable ranges 1A / 100A / 1000A AC
Measuring range 0.001 ÷ 1.2A / 0.1 ÷ 120A / 1A ÷ 1200A AC
Output signal 1V AC
Protection By diodes
Ratio 1mV/mA – 10mV/A - 1mV/A
Max error 2% (of reading)
Internal load 1A=3kΩ; 100A=15Ω; 1000A=1.5Ω
External min load 100 times the internal load
Power measurement Take care to keep the conventional direction P1 ⇒ P2 of the arrow
Frequency range 40Hz ÷ 10kHz
Pollution degree 2 according to IEC 1010-1
Dielectric strength 5,5 KV 50 Hz 1 min
Temperature range -10 ÷ +50 °C
Overvoltage category CAT III 600V
Max cable diameter 54 mm
Max bus bars 35x35mm or 50x12mm
Dimensions 105 x 225 x 31 mm
Weight 720 g
Output connection Cable 2m with Hypertac connector
Accuracy — 1A FS
1 ÷ 100mA — Precision in %rdg of output signal ±(3%rdg + 0.5mV)
1 ÷ 100mA — Phase difference Not specified
100 ÷ 500mA — Precision in %rdg of output signal ±(2%rdg + 1mV)
100 ÷ 500mA — Phase difference Not specified
500mA ÷ 1.2A — Precision in %rdg of output signal ±(1%rdg +1mV)
500mA ÷ 1.2A — Phase difference <10 degrees
Accuracy — 100A FS
100mA ÷ 1A — Precision in %rdg of output signal ±(1%rdg + 1mV)
100mA ÷ 1A — Phase difference Not specified
1 ÷ 10A — Precision in %rdg of output signal ±(0.5%rdg +0.5mV)
1 ÷ 10A — Phase difference 2 degrees
10 ÷ 120A — Precision in %rdg of output signal ±(0.5%rdg)
10 ÷ 120A — Phase difference 1 degrees
Accuracy — 1000A FS
1 ÷ 10A — Precision in %rdg of output signal ±(1%rdg + 0.5mV)
1 ÷ 10A — Phase difference Not specified
10 ÷ 100A — Precision in %rdg of output signal ±(0.5%rdg +1mV)
10 ÷ 100A — Phase difference 1.5 degrees
100 ÷ 1200A — Precision in %rdg of output signal ±(0.5%rdg)
100 ÷ 1200A — Phase difference 1 degrees
Important: For power measurement, maintain the conventional current direction P1 ⇒ P2 indicated by the arrow.
Important: Overvoltage category CAT III 600V; pollution degree 2 according to IEC 1010-1; dielectric strength 5.5 KV 50 Hz 1 min.
Important: The external minimum load must be at least 100 times the internal load (internal load: 1A=3kΩ; 100A=15Ω; 1000A=1.5Ω).

About this New unit

This is a brand-new, factory-sealed unit, supplied exactly as it arrives from the manufacturer and backed by the full manufacturer warranty. For the exact configuration, available options, included accessories, or current lead time for your application, our Test Architects can confirm the details before you order.

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

HT Italia HT96U 1-100-1000A/1V AC Current Transducer Clamp

Item no : 51001731404
sold recently : Login >>
US$ 247.50
Pay in 4 interest-free payments of $61.88 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 23 - Jun 28

Enjoy 20% off shipping

US$ 247.50

1-11

US$ 222.75

12-35

US$ 173.25

36-59

US$ 148.50

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches